Posty: 98 #998898 Od: 2011-5-12
| Po wieczornej rozmowie z Leszkiem OBH postanowiłem pogrzebać w konfiguracji WX i jak ustaliliśmy beacons przestawiłem na 30min tylko przemiennik został na 5min. Przez przypadek wszedłem też na www producenta i jest sporo aktualizacji WX. Myślę że do czwartku uda mi się wgrać nowy soft w urządzenie i postaram się w czwartek przynieść graty do klubu to wspólnie coś jeszcze uradzimy. a oto lista zmian w nowym sofcie
- full WXTelemetry module support
v1.25 - revision of ax.25 reception algorithm, optimisation and simplification of the code, - bug fix for WS-23XX data reception algorithm, these stations sometimes send faulty wind speed values which need to be ignored
v1.26BETA - THIS IS A BETA RELEASE, THERE WERE SO MANY CHANGES THAT SURELY SOMETHING WILL NOT WORK  - many changes and code cleanups invisible for end user, - rewritten beacon configuration allowing to define regional paths, - added DNS client support, - added NTP client support, - updated web interface, - added telnet connection for better understanding of whats going on in the device and debuging (tested with Putty), - changes in weather and telemetry reports configuration,
v1.26b - some minor fixes based on user comments, - changed and extended DNS and NTP debug messages in telnet, - added time in telnet messages, - DNS answer lifetime for NTP servers reduced, this should allow to select next NTP server IP from DNS when there is no answer from previous one (I observed that most NTP server domain answers send random next server from the server pool), - I've also noticed that NTP servers doesn't answer on every query UDP packet, this is probably normal for UDP connection so please dont be alarmed if there are NTP query retries a few times, - debug ax25 on/off fixed, - some field validation error messages fixed in Configurator application, - configuration import/export to a text file na Configurator application, - added version checking between Configurator application and device configuration, now it is not possible to download configuration from the device if its version number is different than application version number (from now on please use easy configuration import/export to transfer configuration between versions, export it in older Configurator version and then import in new Configurator version, this unfortunately works starting from version 1.26b), - configuration version checking in the device, now it is not possible to run the device with different firmware and configuration versions, this caused to much unpredictable problems when users tried to upgrade firmware and leave old configuration, device will simply blink all its leds and not start - these two above changes are made for our common good and not to limit someone 
v1.27 - this official release includes all changes from v1.26BETA and v1.26b (see above), - rewritten APRS-IS -> RF messaging code, third party paths of RF messages are now generated properly, according to APRS specs; some antiflood protections added in APRS-IS messages parsing, - added digihops calculation function based on received RF packets paths, - new debug command in telnet: "print rfheard" - prints all callsigns heard within <= 2 digihops vicinity, - corrected humidity readings for Davis weatherstations, - callsign and APRS-IS login are now forced upper-case for compatibility with new javAPRSSrvr, - device logins to APRS-IS network as WX3in1Plus <version> instead of WX3in1 Plus <version> for compatibility reasons. _________________ 73! Michał SQ7PGP |